01A heat pump moves heat instead of making it
A resistive element turns one unit of electricity into roughly one unit of heat. A heat pump uses a refrigeration cycle to move heat from outside air into the room, so it can deliver several units of heat per unit of electricity. That ratio falls as the outside air gets colder, which is why the technology suits mild climates well.
02Cape winters are mild but humid
Temperatures rarely approach the cold limits that heat pumps are designed for, so capacity is not usually the problem. Humidity is. Damp air condenses and freezes on the outdoor coil, and the unit periodically reverses into defrost to clear it. That is normal operation, not a fault.
A unit that defrosts constantly, or one that ices up and stays iced, points to a sensor, airflow or refrigerant fault. Persistent icing also happens when a unit is undersized or mounted in a poorly ventilated spot.
03What determines running cost
- How well the room is insulated and how draughty it is
- Whether the unit is correctly sized for the space
- The temperature you ask for: every degree above comfort adds cost
- How the unit is used, steady background heating versus heating a cold room hard
- Outdoor unit placement, which affects both efficiency and defrost behaviour
- Whether filters and coils are clean
04Hot-water heat pumps are a different calculation
An air-source hot-water heat pump heats a cylinder rather than a room. It needs a well-ventilated position with enough air volume and somewhere for the cold discharge to go, and it needs to be sized to the household's hot-water use. Where it is well applied it can cut water-heating electricity substantially compared with a resistive element; where it is squeezed into a closed cupboard it will underperform.
05Using a reverse-cycle unit well
- Set a comfortable temperature and leave it rather than swinging it up and down
- Point the louvres down in heating mode, since warm air rises
- Close doors to rooms you are not heating
- Fix draughts and consider heavier curtains before buying a bigger unit
- Run the unit periodically in summer so seals and valves do not seize
06Maintenance that keeps efficiency
Clean filters, a clean outdoor coil, clear condensate drainage and sound insulation on the pipework cover most of it. On the coast, add coil corrosion inspection: a heat pump works year-round, so its outdoor coil sees more salt exposure than a cooling-only unit.